Preview

Problems of Particularly Dangerous Infections

Advanced search

Application of Risk Assessment Methodology for Substantiation of Measures Complex on Provision of Safe Functioning of Mobile Laboratories of Specialized Anti-Epidemic Teams

https://doi.org/10.21055/0370-1069-2011-2(108)-22-26

Abstract

A set of risk assessment methods was used for substantiation of safe functioning of mobile laboratories (ML) of specialized anti-epidemic teams (SAET). The utilized methods were borrowed from diverse spheres of activity and recommended for evaluation of biological hazard and risk associated with work with pathogenic biological agents. The obtained data represent the basis for biorisk management in SAET` ML functioning.

About the Authors

M. V. Pchelintseva
Russian Research Anti-Plague Institute Microbe
Russian Federation


M. N. Lyapin
Russian Research Anti-Plague Institute Microbe
Russian Federation


I. N. Ezhov
Russian Research Anti-Plague Institute Microbe
Russian Federation


A. V. Toporkov
Russian Research Anti-Plague Institute Microbe
Russian Federation


References

1. [Sanitary and Epidemiological Regulations “Safety of Work with the Microorganisms of I–II Pathogenicity (Hazard) Groups”: SR 1.3.1285-03]. Bul. Norm. Method. Dok. Gossanepidnadzor. 2003; 3(13): 61–144.

2. [Sanitary and Epidemiological Regulations “Safety of Work with the Microorganisms of III–IV Pathogenicity (Hazard) Groups and Parasitic Diseases Agents”: SR 1.3.2322-08]. Bul. Norm. Method. Dok. Gossanepidnadzor. 2009; 4(38): 13–66.

3. Onischenko G.G., Toporkov A.V., Toporkov V.P., Koulichenko A.N., Kutyrev V.V. [Specialized anti-epidemic teams (SAET): the experience of work and tactics of their employment in modern conditions]. Probl. Osobo Opasn. Infek. 2008; 4(98): 5–14.

4. [Practical Guide on Biological Safety in Laboratory Conditions]. 3-rd Ed. Geneva:WHO; 2004. 190 p.

5. Cherkasskii B.L. [Risk in Epidemiology]. M.: Prakticheskaya Meditsina; 2007. 480 p.

6. Chernova G.V., Kudriavtsev A.A. [Risk Management]. M.: TK Velbi; 2003. 160 p

7. Laboratory biorisk management standard CWA 15793:2008 (E). [cited 10 Nov 2010]. Available from: ftp://ftp.cenorm.be/PUBLIC/CWAs/workshop31/CWA15793.pdf.


Review

For citations:


Pchelintseva M.V., Lyapin M.N., Ezhov I.N., Toporkov A.V. Application of Risk Assessment Methodology for Substantiation of Measures Complex on Provision of Safe Functioning of Mobile Laboratories of Specialized Anti-Epidemic Teams. Problems of Particularly Dangerous Infections. 2011;(2(108)):22-26. (In Russ.) https://doi.org/10.21055/0370-1069-2011-2(108)-22-26

Views: 460


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 0370-1069 (Print)
ISSN 2658-719X (Online)